+84 2438612612
CÔNG TY TNHH THIẾT BỊ KHOA HỌC KỸ THUẬT AN DƯƠNG
info@adgroup.vn
Colorlib Template

Đầu dò Falcon 4i

Hãng sản xuất: Thermo Fisher Scientific

Giá bán: Đang cập nhật

Liên hệ ngay

Đầu dò điện tử trực tiếp với chất lượng hình ảnh nâng cao, nén dữ liệu hiệu quả và năng suất.


Direct electron detector camera for cryo-EM

The Thermo Scientific Falcon 4i Direct Electron Detector is the ideal solution for your single particle analysis  and  cryo-tomography applications. With its unique combination of high image quality, high throughput, efficient lossless data compression enabled via electron-event representation (EER), and a streamlined solution for data management and quality monitoring, the Falcon 4i Detector offers a productivity and performance boost that meets the demands of today’s scientific and industrial communities.

The Falcon 4i Detector is fully integrated in Thermo Scientific EPU and Tomography Software, allowing for smooth daily instrument operation and data acquisition. The camera’s output is recorded through the Data Management Platform (DMP), which also facilitates the organization, viewing, and sharing of single particle cryo-EM data. You can easily view all the project data and metadata at the microscope or remotely through a secure connection, and can comment and share it with collaborators.

Note: The Falcon 4i Direct Electron Detector is fully compatible with 200 and 300 kV Thermo Scientific Krios, Glacios, and Talos Cryo-Transmission Electron Microscopes (Cryo-TEMs) operating with Windows 10. A Falcon 4i Upgrade Kit is available for the Falcon 4 Direct Electron Detector. The Falcon 4i Upgrade Kit upgrade is also applicable for the Thermo Scientific Selectris and Selectris X Imaging Filters.

 

 

Direct electron detector camera for cryo-EM
Thermo Scientific Falcon 4i Direct Electron Detector

Selectris and Selectris X Imaging Filters

Designed for stability and speed, the Thermo Scientific Selectris and Selectris X Imaging Filters are post-column imaging filters that improve the contrast of TEM images, resulting in high-resolution structures up to atomic resolution. Paired with the latest generation Thermo Scientific Falcon 4i Direct Electron Detector, Selectris Filters enable you to obtain high-resolution structures quickly, revealing new biological insights. To further increase the productivity and ease-of-use of your cryo-electron microscopy (cryo-EM) research, these filters are fully integrated into Thermo Scientific EPU SoftwareThermo Scientific Tomography Software, and instrument operation software. The Selectris and Selectris X Imaging Filters are available on Thermo Scientific Krios and Glacios Cryo-TEMs.

Learn more


The Falcon 4i Direct Electron Detector enables high resolution and throughput.

Appoferritin

Apoferritin reconstruction at 1.2 Å resolution created from 3,600 images of 297k particles acquired in 6 hours (EPU data acquisition on the Thermo Scientific Krios G4 Cryo-TEM). Recorded at a dose rate of 5.4 e/p/s.

Amyliod

Amyloid-β 42 filaments isolated from human brain resulting in a 2.5 Å resolution reconstruction. Data collected at dose rate 8 e/p/s, 40 e/A2 total dose and 570 movies/hr. Collaboration with MRC Laboratory of Molecular Biology. doi: https://doi.org/10.1101/2021.10.19.464936

 

 

Key Features

Unsurpassed image quality through higher DQE

Get leading detective quantum efficiency (DQE) across the full spatial frequency range. High DQE at low spatial frequency lets you visualize and align smaller and more flexible proteins, while high DQE at high spatial frequencies lets you achieve results with fewer images or increased resolution.

Direct electron detector camera for cryo-EM

Large pixels with high signal-to-noise ratio (SNR)

The large signal generated by the Falcon 4i Detector’s large pixels, combined with low noise, yields high SNR – electron events can be unambiguously separated from the background noise (left) in comparison to detectors with smaller pixels (right).

Falcon-4i-large-pixel-1000

Higher throughput for more images per hour

The increased internal frame rate, in combination with improved overhead, yields a significant increase in throughput, depending on the use case.

More-imgs-per-hour

Lossless data compression with electron-event representation (EER)

Electron-event representation (EER) data enables efficient cryo-EM file storage with full preservation of spatial and temporal resolution. Counted events of all raw frames are available for processing with full temporal resolution (320 fps) and spatial resolution (events are localized to one-sixteenth of a pixel). This super resolution capability maximizes the benefit of the Falcon 4i Detector’s superior DQE at high spatial frequencies.

Full-temporal-resolution-v2

 

Specifications

 

Camera architectureDirect electron detection
Sensor size4,096 × 4,096 pixels, ~ 5.7 x 5.7 cm2
Pixel size14 x 14 μm2
TEM Operating voltage200 kV, 300 kV
Internal frame rate320 fps
Frame rate to storage320 fps (EER mode)
Camera Overhead time0.5 s per acquisition
File formatsEER (native), MRC, TIFF, LZW TIFF
Lifetime (<10% DQE degradation)5 years in normal use (1.5Ge/px)
Detection ModesElectron counting mode
Survey mode (fast linear mode)
Imaging performance in EER mode (4k x 4k)300 kV200 kV
DQE (0)0.920.91
DQE (½ Nq)0.720.62
DQE (1 Nq)0.500.33